Lithium Iron Phosphate Batteries, LiFePO4
| Project |
|
|
|
|
|
48V 20AH LFP |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Battery Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Battery Model |
|
|
|
|
SE16S20RFE |
|
|
|
|
|
|
|
|
| Voltage |
|
|
|
|
|
48 Volts |
|
|
|
|
|
|
|
|
|
| Operating Voltage |
|
|
|
|
45V - 54V |
|
|
|
|
|
|
|
|
| Rated Capacity |
|
|
|
|
20 AH |
at C/2 rate |
|
|
|
|
|
|
|
| Type |
|
|
|
|
|
LiFePO4 |
|
|
|
|
|
|
|
|
|
| Body |
|
|
|
|
|
Alumnium Casing |
|
|
|
|
|
|
|
|
| Weight |
|
|
|
|
|
12 Kg (approx.) |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dimensions : |
|
|
|
|
(dimension are indicative and approx., exact dimension will be after making the battery) |
|
| Length |
|
|
|
|
|
320 mm |
|
|
|
|
|
|
|
|
|
| Width |
|
|
|
|
|
145 mm |
|
|
|
|
|
|
|
|
|
| Height |
|
|
|
|
|
120 mm |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BMS Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
| BMS Model |
|
|
|
|
PS-L16S30-471/A |
|
|
|
|
|
|
|
|
| Desscription |
|
|
|
|
Complete Li-Ion control, monitoring, and safety solution designed for large series cell strings |
| Type |
|
|
|
|
|
Power Pump, Cell Balancing Function |
|
|
|
|
|
|
| Current consumption for single cell |
|
|
20uA |
|
|
|
|
|
|
|
|
|
| Maximal continuous charging and discharging current |
25A |
|
|
|
|
|
|
|
|
|
| Over charge detection voltage |
|
|
3.8 -4.4V can adjust |
|
|
|
|
|
|
|
| Over charge detection delay time |
|
|
0.5~2.5S |
|
|
|
|
|
|
|
|
|
| Over charge release voltage |
|
|
|
3.8 -4.4V can adjust |
|
|
|
|
|
|
|
| Over discharge detection voltage |
|
|
1.9-3.1V can adjust |
|
|
|
|
|
|
|
| Over discharge detection delay time |
|
|
50~300mS |
|
|
|
|
|
|
|
|
| Over discharge release voltage |
|
|
1.9-3.1V can adjust |
|
|
|
|
|
|
|
| Over current detection voltage |
|
|
0.6V |
|
|
|
|
|
|
|
|
|
| Over current detection current |
|
|
80 - 200A |
|
|
|
|
|
|
|
|
| Detection delay time |
|
|
|
1~50ms |
|
|
|
|
|
|
|
|
|
| Release condition |
|
|
|
|
Cut load |
|
|
|
|
|
|
|
|
|
| Detection condition |
|
|
|
Exterior short circuit |
|
|
|
|
|
|
|
| Detection delay time |
|
|
|
200-500us |
|
|
|
|
|
|
|
|
| Release condition |
|
|
|
|
Cut load |
|
|
|
|
|
|
|
|
|
Protection circuitry B- to P-
|
|
|
20m |
|
|
|
|
|
|
|
|
|
| Operating temperature range |
|
|
-40C to +85C |
|
|
|
|
|
|
|
|
| Storage temperature range |
|
|
|
-40C to +125C |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cell Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cell Model |
|
|
|
|
7568270RF |
|
|
|
|
|
|
|
|
| Voltage / Rating |
|
|
|
|
3.2V / 10A at C/2 rate |
|
|
|
|
|
|
|
| Dimension |
|
|
|
|
270 x 68.5 x 7.6 mm |
|
|
|
|
|
|
|
|